MSZ-LN sulatushuijaus

iro

Vakionaama
Uusi MItsurunner release (2026_1) löytyy nyt githubista.

ESP8266 pohjaiseen Wemosiin jokunen pieni muutos/korjaus sekä mahdollisuus lisätä adaptiivinen säälisulatus ja edellisten lämmitysjaksojen pituuden seuranta WEB-näkymässä.
ESP32 pohjaiseen Sonoff Eliteen (THR316D) hiukan enemmän muutosia.
Alla Release Note;

Release Overview
================

This MitsuRunner release supports two hardware platforms:
* ESP8266‑based Wemos, and
* ESP32‑based Sonoff Elite THR316D.

Data can be transmitted via MQTT to IoT‑Guru, a local MQTT broker, or to Home Assistant using the HA API.

This release also includes two optional add‑on features:
* Time‑out defrosting adjusted according to outdoor temperature
* Heating cycle length calculation with WEB‑view display

Configuration is now built by including selected YAML modules, instead of editing a single monolithic configuration file. This modular structure makes the setup cleaner, more flexible, and easier to maintain.


Changes from previous release
=============================

mitsu_conf.yaml
Added new selectable modules for compilation and building.

mitsurunner.yaml
Device stays in reset state until Dallas sensors have received valid readings.
Adjustments for the adaptive_heating_timeout module.

MQTT_Guru.yaml, MQTT_local.yaml
Updated for compatibility with future ESPHome versions.

platform_wemos.yaml
Added feature to display MitsuRunner version in the WEB view.
WiFi, HA, and MQTT time‑out increased from 6 hours to 10 hours.

platform_elite.yaml
Updated for compatibility with ESPHome 2026.
WiFi, HA, and MQTT time‑out increased from 6 hours to 10 hours.
Added WiFi AP‑mode and captive portal (activated if WiFi is lost for more than 2 minutes).
User interface improvements (LEDs and display).

secrets_elite.yaml (new)
Dedicated configuration file for Sonoff Elite THR316D devices.

adaptive_heating_timeout.yaml (new optional feature)
Outdoor‑temperature‑based adaptive maximum heating time:
Missing outdoor value → default = 3h
Above −10 °C → default + 3h = 6h
Between −10 °C and −20 °C → default + 1.5h = 4.5h
Below −20 °C → default = 3h

heating_cycle.yaml
Calculates heating cycle durations and displays them in the WEB view and Home Assistant.(new optional feature)
 

johnblon

Jäsen
Terve! Mulla on tosiaan tuo Sonoff elite ja puu:n adapteri. Jos annan kytkennät olla ja otan vain virrat pois laitteesta, niin toimiiko se niin kuin aiemmin, eli mitsu näkee/käyttää sitä omaa lämpötila-anturia?
 

iro

Vakionaama
Terve! Mulla on tosiaan tuo Sonoff elite ja puu:n adapteri. Jos annan kytkennät olla ja otan vain virrat pois laitteesta, niin toimiiko se niin kuin aiemmin, eli mitsu näkee/käyttää sitä omaa lämpötila-anturia?
Kun Mitsurunner on virrattomana niin Mitsu toimii täysin normaalisti. Myös jos WEB-näkymästä laittaa "Mitsurunner enabled" vivun OFF-asentoon Mitsu toimii normaalisti mutta ulko- ja kennolämmöt mitataan ja raportoidaan.
 

iro

Vakionaama
:grandpa::grandpa:Laitan tänne taas muistutuksen liittyen Mitsurunner/IoT-Guru-käytöön.:grandpa::grandpa:

IoT-Guru poistaa satunnaisin aikavälein "Devicet" joita ei ole käytetty pitkään aikaan. Jos näin käy täytyy Device:t tehdä IoT-Guruun uudelleen ja MQTT-parametit päivittä myös Mitsuruner koodiin
Tämän välttämiseksi kannatta Mitsurunner pitää (ainakin ajoittain) käytössä myös kesäaikaan.
 

puu

Aktiivinen jäsen
Kun Mitsurunner on virrattomana niin Mitsu toimii täysin normaalisti. Myös jos WEB-näkymästä laittaa "Mitsurunner enabled" vivun OFF-asentoon Mitsu toimii normaalisti mutta ulko- ja kennolämmöt mitataan ja raportoidaan.
Tosin olikos tässä niin, että jos Mitsurunner boottaa, niin se menee taas on-asentoon?
 
Mitähän tässä on mahtanut tapahtua ? Lauantaina kytkin ”huijaus anturin” koneeseen kiinni. Tätä ennen on mitsurunneri ollut pari viikkoa mittailemassa kennoa ja ulkoilman lämpöjä ja näyttänyt toimivan ihan ihan normaalisti.

IMG_2860.jpeg
 

Liitteet

  • IMG_2861.jpeg
    IMG_2861.jpeg
    90,5 KB · Katsottu: 7
  • IMG_2862.jpeg
    IMG_2862.jpeg
    94,7 KB · Katsottu: 4
  • IMG_2863.jpeg
    IMG_2863.jpeg
    99,6 KB · Katsottu: 4
  • IMG_2864.jpeg
    IMG_2864.jpeg
    100,9 KB · Katsottu: 7
  • IMG_2865.jpeg
    IMG_2865.jpeg
    83,4 KB · Katsottu: 5

iro

Vakionaama
Mahtaakohan pumppu toimia nyt normaalisti vaikka anturit mykkänä. Pumppu on mökillä ja ei olla nyt seuraavaan viikkoon menossa.
Koska tila on 3 eli "lupa sulattaa" pumppu toiminee normaalisti. Time-outin kautta tila käy välillä arvossa 0, mutta tuo tuskin vaikuttaa pumpun toimintaan.
Uudessa Mitsurunnerin softassa on lisäehto: tila pysyy arvossa -3 (st_off) kunnes dallas-antureilta saadaan kelvolliset lukemat. Ei korjaa juurisyytä mutta varmistaa ettei mitään epätoivottua tapahdu.
 

tmns

Jäsen
Uusi MItsurunner release (2026_1) löytyy nyt githubista.

ESP8266 pohjaiseen Wemosiin jokunen pieni muutos/korjaus sekä mahdollisuus lisätä adaptiivinen säälisulatus ja edellisten lämmitysjaksojen pituuden seuranta WEB-näkymässä.
ESP32 pohjaiseen Sonoff Eliteen (THR316D) hiukan enemmän muutosia.
Alla Release Note;

Release Overview
================

This MitsuRunner release supports two hardware platforms:
* ESP8266‑based Wemos, and
* ESP32‑based Sonoff Elite THR316D.

Data can be transmitted via MQTT to IoT‑Guru, a local MQTT broker, or to Home Assistant using the HA API.

This release also includes two optional add‑on features:
* Time‑out defrosting adjusted according to outdoor temperature
* Heating cycle length calculation with WEB‑view display

Configuration is now built by including selected YAML modules, instead of editing a single monolithic configuration file. This modular structure makes the setup cleaner, more flexible, and easier to maintain.


Changes from previous release
=============================

mitsu_conf.yaml
Added new selectable modules for compilation and building.

mitsurunner.yaml
Device stays in reset state until Dallas sensors have received valid readings.
Adjustments for the adaptive_heating_timeout module.

MQTT_Guru.yaml, MQTT_local.yaml
Updated for compatibility with future ESPHome versions.

platform_wemos.yaml
Added feature to display MitsuRunner version in the WEB view.
WiFi, HA, and MQTT time‑out increased from 6 hours to 10 hours.

platform_elite.yaml
Updated for compatibility with ESPHome 2026.
WiFi, HA, and MQTT time‑out increased from 6 hours to 10 hours.
Added WiFi AP‑mode and captive portal (activated if WiFi is lost for more than 2 minutes).
User interface improvements (LEDs and display).

secrets_elite.yaml (new)
Dedicated configuration file for Sonoff Elite THR316D devices.

adaptive_heating_timeout.yaml (new optional feature)
Outdoor‑temperature‑based adaptive maximum heating time:
Missing outdoor value → default = 3h
Above −10 °C → default + 3h = 6h
Between −10 °C and −20 °C → default + 1.5h = 4.5h
Below −20 °C → default = 3h

heating_cycle.yaml
Calculates heating cycle durations and displays them in the WEB view and Home Assistant.(new optional feature)
Olisiko tämän päivityksen tekemiseen joku simppeli rautalankaohje? Pystyykö tuon tekemään wifin yli vai pitääkö aloittaa ns. "tyhjästä" ja mennä piuhalla kiinni runneriin?
 

iro

Vakionaama
Olisiko tämän päivityksen tekemiseen joku simppeli rautalankaohje? Pystyykö tuon tekemään wifin yli vai pitääkö aloittaa ns. "tyhjästä" ja mennä piuhalla kiinni runneriin?
Täällä ohjeita

Eli tiivistetysti: lataa paketti github:sta, mitsu_conf.yaml tiedostossa valitse haluttu konfiguraatio ja yksittäisiin *.yaml tiedostoihin päivitä halutut parametrit (WiFi ja OTA, GPIO-nastat, Dallas-IDt, MQTT-parametrit).
Jos WiFi- ja OTA-parametrit ovat samat kun Mitsurunnerissa nyt olevat OTA-päivitys onnisttu.
 

haraldh

Vakionaama
PItää varmaan ottaa talteen ainakin api encryption key, ap ssid password (fallback hotspot) sekä ota platform password vanhasta YAML-konffista. Sekä pinni konfiguraatiot ja dallas osoitteet platform_wemos.yaml tiedostosta. Jos on muuttanut constants.h tiedostosta jotain pitää nekin siirtää. Ja jos MQTT käytössä niin sen tiedot.

Kyllä tuossa on pientä uudelleen perehtymistä luvassa jos haluaa päivittää uusiin tiedostoversioihin.
 

tmns

Jäsen
Täällä ohjeita

Eli tiivistetysti: lataa paketti github:sta, mitsu_conf.yaml tiedostossa valitse haluttu konfiguraatio ja yksittäisiin *.yaml tiedostoihin päivitä halutut parametrit (WiFi ja OTA, GPIO-nastat, Dallas-IDt, MQTT-parametrit).
Jos WiFi- ja OTA-parametrit ovat samat kun Mitsurunnerissa nyt olevat OTA-päivitys onnisttu.
Kiitoksia, lähdetäänpä tässä jossain vaiheessa koittamaan. Tarkoitus oli muutenkin tehdä pieni muutos, että mittausdata menisi jatkossa IoTGurun sijasta HomeAssistantiin.
 

iro

Vakionaama
Kiitoksia, lähdetäänpä tässä jossain vaiheessa koittamaan. Tarkoitus oli muutenkin tehdä pieni muutos, että mittausdata menisi jatkossa IoTGurun sijasta HomeAssistantiin.
Mitsurunnerin Wemos paketissa ei ole määritelty fall_back ap hotspottia eikä api-encryption-key:tä. Jos noita ei ole erikseen lisätty niin noita ei tarvita myöskään uudessa koodissa.

Siirtymä Gurusta HomeAssistanttiin on helppo. Mitsu_conf.yaml:ssä käytä mqtt_Guru.yaml tilalla mqtt_disabled.yaml tiedostoa ja platform_wemos.yaml tiedostossa poista kommenttimerkit rivien api osion rivien edestä.

Koodi:
# Enable/disabe HomeAssistant
api:                                       # !! If home Assistant in use remove comment (#)
  reboot_timeout: $common_reboot_timeout   # !! If home Assistant in use remove comment (#)
#####################

Ja samalla kun teet tuon muutoksen päivitä DallasID:t ja tarvittaessa GPIO-pin käytön.
Secrets tiedostoon päivitä WiFi- a OTA-patametrit.
Jos olet tehnyt muutoksia constants-tiedostoon voit käyttää tuota tiedostoa.
Sitten vaan käännät ja OTA-lataa uusi image Mitsurunneriin. :sille:
 
Viimeksi muokattu:

haraldh

Vakionaama
Minulla oli Tasmota-pohjainen ESP joka mittasi lämpötiloja Ilmava LTO:ssa. Kyllä senkin sai OTA:na päivitettyä Esphomeksi. Sen kun ensin OTA Tasmota minimal versioon jotta sai tilaa, ja sitten Home Assistantin Esphome:ssa käännetty binääri verkkosivunsa kautta. Nousi verkkoon ja sain yhteyden, yllätyin miten hyvin toimi.
 

haraldh

Vakionaama
Mitä v*ttua luulin että sekoilu jo loppui tälle kaudelle.

Never stop the madness.

Ulkona 2⁰C ja ajattelin että sulatuksia ei tarvitse. Purista runsaan tunnin verran 5 kW lämpöä LN25v2 laitteesta kun samalla täällä saaristossa kaikki laivat soittavat sumutorvea sankan sumu johdosta.

Kai se tarvitsi sulatusta, ja puolitoista tuntia se antoi lämpöä.

1000052554.jpg



Äänet päälle;
 
Viimeksi muokattu:
Back
Ylös Bottom